A specialist marketplace by BottlingScoutBottlingScout.com ↗

Compare five filling heads on a used oil filler

Compare five heads on a used oil filler using two recorded net-weight trials by head and a clearly stated example tolerance.

Italiano

Select five identified heads and note the order of the start and sampling. Use the same oil, container lot and approved net-weight method. Before evaluating a machine, agree which acceptance criterion applies and whether the trial covers startup, steady production or both.

Record readings individually before summarising

Illustrative two-round trial. The example band is 462–468 g.
HeadRound ARound BOutside the illustrative band
1465 g466 g0
2464 g465 g0
3467 g466 g0
4459 g460 g2
5465 g467 g0

Keep the head pattern visible

Head 4 falls outside the illustrated band on both readings. This is a starting point for a repeated approved test and qualified inspection. The values and band are examples, not a release specification. Record individual tare where the chosen method requires it and retain the underlying values.

Attach oil conditions, required size, measured run state and the filler model to the request. Clarify whether the offered machine can be tested at the intended application and what outcome would close the inspection.

Review the technical choice of a used filling machine

Request a used oil filler comparison with the five head readings, product details and the required verification method.

WhatsApp